Thoracic Impedance Tomography VenTom-100A/B/C
+
  • Thoracic Impedance Tomography VenTom-100A/B/C

Thoracic Impedance Tomography VenTom-100A/B/C

Electrical Impedance Imaging EIT, is a non-invasive medical imaging technique. It measures changes in the impedance of different tissues to electrical currents by placing electrodes on the surface of the body and uses this data to generate two-dimensional images. Because the ventilatory activity of the lungs can lead to significant changes in impedance, this technique is particularly well suited for monitoring the state of respiratory function .

Keywords: Thoracic Impedance Tomography VenTom-100A/B/C

Product Inquiry

Product Details

Electrical Impedance Tomography

What can ElT (electrical impedance tomography) do?

Current methods cannot meet the needs for real-time, dynamic, bedside assessment of lung status.

CT or X-ray

Structural imaging with low temporal resolution

Cannot capture ventilation changes in real time

Radiation exposure, unsuitable for bedside monitoring

Lung ultrasound

Insensitive to ventilation changes

Low image quality, discontinuity

High operator requirements

Lung function

Average function, poor regional sensitivity

Requires high patient cooperation

Unable to perform dynamic imaging

Clinical Applications

EIT can support the entire ventilation management process and improve prognosis.

For relevant clinical consensus, see the 2022 "Chinese Medical Journal": Clinical Application of Lung Electrical Impedance Imaging Technology in Critical Respiratory Management: Chinese Expert Consensus

What problems can we solve? Precise diagnosis and efficacy evaluation guidance in critical respiratory care and cardiopulmonary rehabilitation treatment.

Application Scenarios

VenTOM-100

What is VenTOM-100?

A new device to cardiopulmonary monitoring and diagnosis that revolutionizes ventilation, blood flow, lung function, and rehabilitation.

What are the advantages of VenTOM-100?

High-sensitivity current stimulation method 
AI deep training and noise suppression EIT algorithm 
Individualized a aprior information reconstruction EIT image

VenTOM-100 (A/B/C)

9+5 specifications and models, suitable for chest circumferences of 36cm~150cm

New generation EIT imaging equipment: MidasMED VenTOM-100

Disposable/Reusable electrode strips

Features:

Non-invasive/no wire connection required

No risk of cross-infection

Fast current conduction, high consistency

Clinical application scenarios (wireless transmission)

Clinical analysis (ventilation/perfusion)

Features: 
Real-time imaging, PEEP titration, pre- and post-reinflation blood perfusion, pulsatile information, pendulum breathing

Portable integrated unit

Features: 
Wireless, handheld transport, time-sharing connection of different collection boxes

EIT signal acquisition box

Features: 
Wireless remote

Market Demand

Applications of Electrical Impedance Imaging

As an imaging method different from traditional CT and X-ray, electrical impedance imaging can meet the needs of real-time, dynamic, quantitative, bedside assessment of lung injury and lung ventilation and gas exchange function. The new generation of technology solves many problems of traditional EIT equipment, such as large size, complex operation, difficult image interpretation, and limited clinical application scenarios. With the rapid iteration of EIT technology, it will show irreplaceable advantages in many clinical applications.

Product Inquiry

+86
  • +86 CN
Submit Message